ModbusInfoBuildWriteBoolModbusCommand 方法 (String, Boolean, Byte, Boolean, Byte) |
构建Modbus写入bool数据的核心报文,需要指定地址,长度,站号,是否起始地址0,默认的功能码
To construct the core message that Modbus writes to bool data, you need to specify the address, length, station number, whether the starting address is 0, and the default function code
命名空间:
HslCommunication.ModBus
程序集:
HslCommunication (在 HslCommunication.dll 中) 版本:12.1.2.0 (12.1.2.0)
语法 public static OperateResult<byte[]> BuildWriteBoolModbusCommand(
string address,
bool value,
byte station,
bool isStartWithZero,
byte defaultFunction
)
Public Shared Function BuildWriteBoolModbusCommand (
address As String,
value As Boolean,
station As Byte,
isStartWithZero As Boolean,
defaultFunction As Byte
) As OperateResult(Of Byte())
public:
static OperateResult<array<unsigned char>^>^ BuildWriteBoolModbusCommand(
String^ address,
bool value,
unsigned char station,
bool isStartWithZero,
unsigned char defaultFunction
)
static member BuildWriteBoolModbusCommand :
address : string *
value : bool *
station : byte *
isStartWithZero : bool *
defaultFunction : byte -> OperateResult<byte[]>
参数
- address
- 类型:SystemString
Modbus的富文本地址 - value
- 类型:SystemBoolean
bool的信息 - station
- 类型:SystemByte
默认的站号信息 - isStartWithZero
- 类型:SystemBoolean
起始地址是否从0开始 - defaultFunction
- 类型:SystemByte
默认的功能码
返回值
类型:
OperateResultByte包含最终命令的结果对象
参见