XinJETcpNetWrite 方法 (String, Int16) |
将数据写入到Modbus的单个寄存器上去,需要指定起始地址和数据值,如果富文本地址不指定,默认使用的功能码是 0x06
To write data to a single register of Modbus, you need to specify the start address and data value. If the rich text address is not specified, the default function code is 0x06.
命名空间:
HslCommunication.Profinet.XINJE
程序集:
HslCommunication (在 HslCommunication.dll 中) 版本:12.1.2.0 (12.1.2.0)
语法 public override OperateResult Write(
string address,
short value
)
Public Overrides Function Write (
address As String,
value As Short
) As OperateResult
public:
virtual OperateResult^ Write(
String^ address,
short value
) override
abstract Write :
address : string *
value : int16 -> OperateResult
override Write :
address : string *
value : int16 -> OperateResult
参数
- address
- 类型:SystemString
起始地址,比如"100","x=4;100","s=1;100","s=1;x=4;100" - value
- 类型:SystemInt16
写入的short数据
返回值
类型:
OperateResult是否写入成功
实现
IReadWriteNetWrite(String, Int16)IReadWriteNetWrite(String, Int16)示例
以下为三菱的连接对象示例,其他的设备读写情况参照下面的代码:
MelsecMcNet melsec_net = new MelsecMcNet( "192.168.0.100", 6000 );
melsec_net.Write( "D100", (short)123 );
OperateResult write = melsec_net.Write( "D100", (short)123 );
if (write.IsSuccess)
{
}
else
{
}
参见